Details
|
MODEL |
CWS-6512 |
CWS-6524 |
CWS-6536 |
CWS-10048 |
CWS-10072 |
||||||
|
OUTPUT |
Rated battery voltage |
12V |
24V 24V 36V 48V |
36V |
48V |
72V |
|||||
|
MAX |
Voltage |
15V |
30V |
45V |
60V |
90V |
|||||
|
Current |
5A |
3A |
2A |
2A |
1.5A |
||||||
|
Ripple and Noise |
25℃ |
≤150mVp-p |
≤300mVp-p |
≤450mVp-p |
≤600mVp-p |
≤900mVp-p |
|||||
|
MAX output voltage can be automatically adjusted according to the communication protocol |
|||||||||||
|
Waterproof level |
IP67 |
||||||||||
|
Voltage Accuracy |
≤±3% |
||||||||||
|
Line Regulation |
≤±1% |
||||||||||
|
Load Regulation |
≤±1% |
||||||||||
|
Set-up Time |
≤2S (220Vac@12V BMS; full load) |
||||||||||
|
Temperature Coefficient |
≤±0.02%/℃ |
||||||||||
|
INPUT |
Voltage Range |
90~264Vac , AC INPUT≤165VAC,See De-rated curve |
|||||||||
|
Frequency Range |
45Hz~65Hz |
||||||||||
|
Power Factor @25℃ |
≥0.95 @ 100~230Vac (at full load) |
||||||||||
|
Efficiency (Typical) |
CWS-6512 |
CWS-6524 |
CWS-6536 |
CWS-10048 |
CWS-10072 |
||||||
|
≥90% |
≥92% |
≥93% |
|||||||||
|
25℃ @ 220V, full load |
|||||||||||
|
AC Current (max.) |
<3A@ 100Vac (at full load) |
||||||||||
|
Inrush Current (Typical) |
<50A @ 264Vac;25℃ |
||||||||||
|
PROTECTION |
Over current |
105%~115% Io |
|||||||||
|
Over voltage |
105%~115% Vo |
||||||||||
|
Protection type: Hiccup mode; auto recovery |
|||||||||||
|
Over temperature |
The power supply comes into protection mode when the temperature is greater than 110 °C |
||||||||||
|
Short Circuit |
Long-term mode, auto recovery |
||||||||||
|
ENVIRONMENT |
Operating amb. Temp. & Hum. |
-15℃~50℃; 20%~90%RH No condensing (refer to derating curve) |
|||||||||
|
Storage Temp. & Hum. |
-40℃~85℃; 10%~95%RH No condensing |
||||||||||
|
Vibration |
9-200Hz, 10m/s2; 3.5min./1cycle, 5 periods, each along x, y, z axes |
||||||||||
|
Impulse |
250m/s2, 6ms; 3 times, each along x, y, z axes |
||||||||||
|
Altitude |
3000m |
||||||||||
|
SAFETY &EMC |
Safety Standards |
CE TUV UL FCC |
|||||||||
|
Isolation Voltage |
Input- Output: 3KVac/10mA. Input- Casing: 1.5KVac/10mA. Output- Casing: 0.5KVac/10mA. |
||||||||||
|
Leakage Current@25℃ |
|||||||||||
|
Isolation Resistance |
10M ohms |
||||||||||
|
EMC |
EN55022 CLASS B |
||||||||||
|
ESD |
Compliance to EN6 |
||||||||||
|
Surge |
Compliance to EN6 |
||||||||||
|
OTHERS |
MTBF |
More than 100,000Hrs; MIL-217 Method 2 Components Stress Method |
|||||||||
|
Dimension (L×W×H) |
150×63×33(mm) |
||||||||||
|
Item |
POWER |
CHAREG MODE |
|||||||||
|
AC Turn on |
/ |
||||||||||
|
Standby |
Green Flash |
/ |
|||||||||
|
Charge |
Green |
Red |
|||||||||
|
Full Charge |
Green |
Green |
|||||||||
|
Fail |
/ |
Red Flash |
|||||||||