3KW Enclosed SMPS Power Supply

WhatsApp

微信扫码咨询
Consult now +86-18602087818 Return

Details

1 Summary

The FY-3000W series is a 3000W high-reliability industrial power supply. It has an input range of 90~264VAC and offers several different output voltages from 24V to 48V throughout the series. With an efficiency of up to 92%.

2 AC Input requirements

2.1 Input AC VoltageFrequence

Rated Input

Enable input

MIN

NOM

MAX

100-240Vac

Voltage(Vrms)

90

100-240

264

Frequency(Hz)

47

50-60

63

2.2 Input Current

      The input current should be less than 19.5A

2.3 Inrush Current (Cold Start)

In the ambient temperature of 25, FULL load, cold start conditions: ac input is 240Vac, less than 15A.

2.4 Power Factor

    When the AC input voltage is Vin=230Vac and the Full load, the power factor PF is 0.95

3 DC Output Characteristics

 

3.1 DC output voltage range

Model

DC Output

Minimum

Typical

Maximum

Remark

FY3000-24

24V

23.5V

24V

24.5V

 

FY3000-36

36V

35.5V

36V

36.5V

 

FY3000-48

48V

47. 5V

48V

48.5V

 

AUX

5V

4.8V

5V

5.2V

1A Max

 3.2 Ripple & Noise

Model

Ripple & Noise (mVp-p)

Remark

FY3000-24

240

1. Use oscilloscope with 20MHz bandwidth for test;

2. When measuring, connect a 0.1µF ceramic capacitor and a 10µF electrolytic capacitor between the output end and the ground.

FY3000-36

360

FY3000-48

400

 3.3 Output Current

Model

Current

Remark

FY3000-24

80A

See 4.4 De-rated curve

FY3000-36

70A

FY3000-48

62.5A

 3.4 Efficiency

Model

FY3000-24

FY3000-36

FY3000-48

Remark

Efficiency

90.5%

92%

@220VACFull load

Standby

3W

 

3.5 DC Output Overshoot

The dc output voltage overshoot caused by switching ac power supply or ON/OFF# should be less than 10% of the normal output, and no reverse polarity voltage will be generated.

4 Environment Requirements

4.1 Operating Temperature and Relative Humidity

Operating Ambient Temperature: -40℃ to +70℃>45°C See De-rated curve)

Operating Ambient Relative Humidity: 0%RH to 95%RH

4.2 Storage Temperature and Relative Humidity

 Storage Ambient Temperature: -40℃ to +85℃

Storage Ambient Relative Humidity: 0%RH to 95%RH

4.3 Altitude:4000 m

4.4 De-rated curve

5 Heat dissipation

Fan cooling

6 Protection Requirements

6.1 Output Over Voltage Protection

110%-120% rated output voltage, type: Lock, restart after recovery

6.2 Output Over current Protection

    105-130% rated output current, type: Auto recovery

6.3 Output Short Circuit Protection

The output when the output connection shorted.

6.4 Over temperature Protection  

Overtemperature power supply will protect

6.5 Input Under-voltage & Overvoltage protection

Under-voltage 75-85VACOvervoltage275-285The deviation is greater than 5V.