Details
SPECIFICATION
|
MODEL |
LHS-100012 |
LHS-100024 |
LHS-100036 |
LHS-100048 |
|||
|
OUTPUT |
Rated Voltage |
12V |
24V |
36V |
48V |
||
|
Rated Current |
55A |
41.7A |
27.8A |
20.8A |
|||
|
Ripple and Noise |
25℃ |
≤150mVp-p |
≤300mVp-p |
≤450mVp-p |
≤600mVp-p |
||
|
MAX output voltage can be automatically adjusted according to the communication protocol |
|||||||
|
Voltage Accuracy |
≤±3% |
||||||
|
Line Regulation |
≤±1% |
||||||
|
Load Regulation |
≤±1% |
||||||
|
Set-up Time |
≤2S (220Vac@12V BMS; full load) |
||||||
|
Temperature Coefficient |
≤±0.02%/℃ |
||||||
|
INPUT |
Voltage Range |
90~264Vac , AC INPUT≤165VAC,See De-rated curve |
|||||
|
Frequency Range |
45Hz~65Hz |
||||||
|
Power Factor @25℃ |
≥0.95 @ 100~230Vac (at full load) |
||||||
|
Efficiency (Typical) |
LHS-100012 |
LHS-100024 |
LHS-100036 |
LHS-100048 |
|||
|
≥90% |
≥92% |
≥93% |
|||||
|
25℃ @ 220V, full load |
|||||||
|
AC Current (max.) |
<16A@ 100Vac (at full load) |
||||||
|
Inrush Current (Typical) |
<15A @ 264Vac;25℃ |
||||||
|
PROTECTION |
Over current |
105%~115% Io |
|||||
|
Over voltage |
105%~115% Vo |
||||||
|
Protection type: Hiccup mode; auto recovery |
|||||||
|
Over temperature |
The power supply comes into protection mode when the temperature is greater than 110 °C |
||||||
|
Short Circuit |
Long-term mode, auto recovery |
||||||
|
ENVIRONMENT |
Operating amb. Temp. & Hum. |
-40℃~70℃; 20%~90%RH No condensing (refer to derating curve) |
|||||
|
Storage Temp. & Hum. |
-40℃~85℃; 10%~95%RH No condensing |
||||||
|
Vibration |
9-200Hz, 10m/s2; 3.5min./1cycle, 5 periods, each along x, y, z axes |
||||||
|
Impulse |
250m/s2, 6ms; 3 times, each along x, y, z axes |
||||||
|
Altitude |
3000m |
||||||
|
SAFETY &EMC |
Safety Standards |
CE TUV UL FCC |
|||||
|
Isolation Voltage |
Input- Output: 3KVac/10mA. Input- Casing: 1.5KVac/10mA. Output- Casing: 0.5KVac/10mA. |
||||||
|
Leakage Current@25℃ |
|||||||
|
Isolation Resistance |
10M ohms |
||||||
|
EMC |
EN55032 CLASS A |
||||||
|
ESD |
Compliance to EN6 |
||||||
|
Surge |
Compliance to EN6 |
||||||
|
OTHERS |
MTBF |
More than 100,000Hrs; MIL-217 Method 2 Components Stress Method |
|||||
|
Dimension (L×W×H) |
|||||||