Specification for 12V/3000W+AC bypass American standard sine wave inverter |
Product model |
FY-1722 |
Product Category |
Inverter power supply |
Product specifications |
12VDC/3000W/120VAC+AC bypass inverter |
|
Ⅰ |
Inverter characteristics |
1 |
DC voltage input range |
11-17VDC |
|
2 |
DC rated input voltage |
12.5VDC |
|
3 |
Static input current |
≤1A |
DC input 12.5VDC no-load |
4 |
DC input low voltage alarm |
10.5±0.2VDC |
Lasts for 30 seconds |
5 |
DC input low voltage protection |
10.0±0.2 |
Lasts for 2 seconds |
6 |
DC input low voltage shutdown |
7.5 ± 0.2VDC, changed to 8.5V |
DC input current<1mA |
7 |
DC input low voltage recovery |
12.5±0.3VDC |
Automatic recovery with a 5-minute delay |
8 |
DC input high voltage protection |
17±0.3 VDC |
|
9 |
DC input high voltage recovery |
14.5±0.3V |
Automatic recovery |
10 |
Remote control shutdown machine standby current |
≤20mA |
Remote control consumption |
11 |
Over temperature protection |
≤65℃ |
Maximum temperature of the shell |
12 |
DC input insurance (built-in) |
40A×8 |
|
13 |
DC input polarity reverse protection |
Blow Fuse |
|
14 |
No load AC output voltage |
120VAC±5V |
|
15 |
Full load AC output voltage |
120VAC±5V |
|
16 |
Output rated power |
3000W |
long-term |
17 |
Maximum output power |
6000W |
20ms |
18 |
Output no-load THD |
<3% |
|
19 |
Output load THD |
<5% |
Pure resistance load |
20 |
Output overload protection 1 |
3100~4000w |
Turn off output in 10 seconds |
21 |
Output overload protection 2 |
4000~4500w |
4 seconds to turn off output |
22 |
Output impulse power |
≥6000W |
|
23 |
Communication output frequency |
60±1Hz |
|
24 |
Output voltage waveform |
Pure sine wave |
|
25 |
Output without load |
Inverter output turned off |
1 minute to activate 15 second AC detection |
26 |
Inverter output enabled |
When the load is around 10W |
Load detection |
27 |
Phase to phase short circuit test |
OK |
Product Protection |
28 |
Inverter conversion efficiency |
Maximum efficiency of 90% |
|
AC mains characteristics |
1 |
AC mains input range |
100VAC-120VAC |
|
2 |
AC mains input rated voltage |
120VAC |
|
3 |
AC mains priority |
In the presence of mains electricity |
The product defaults to prioritizing the output of mains power when turned on |
4 |
AC mains input frequency switching point |
Cut out 55 ± 1HZ at low frequency |
When the mains power is lower than one of the parameter voltage and frequency. Switch to inverter output, and when switching back to mains power, the voltage should be checked for 5 minutes before switching back. |
5 |
Low frequency recovery 56 ± 1HZ |
|
6 |
High frequency recovery 64 ± 1HZ |
|
7 |
High frequency cut out at 65 ± 1HZ |
|
8 |
AC mains input voltage switching point |
Low voltage cut out 90V ± 5V |
|
9 |
Low voltage recovery: 100V ± 5V voltage stabilizes for 5 minutes before recovery |
|
10 |
High voltage recovery: 140V ± 5V voltage stabilizes for 5 minutes before recovery |
|
11 |
High voltage cut out 145 ± 5V |
|
12 |
AC/DC switching time |
<18ms |
|
13 |
AC mains power output rated power single channel |
2400±200W |
Product Protection |
14 |
AC mains voltage HOT1+HOT2 |
240VAC |
|
15 |
AC mains HOT1+HOT2 power |
≤4800W |
|
Ⅲ |
Other electrical characteristics |
1 |
LED display |
Inverter work instruction |
Inverted active orange light (always on) |
2 |
AC mains power indication |
(AC pass through) Green light (always on) |
3 |
Protection instructions |
(Warning) Red light flashing |
4 |
Power indicator |
(Power) Green light (always on) |
5 |
Searching mode |
(Inverted active) Orange light flashing |
6 |
Wired remote control |
Wired 15 meter remote control |
Functions such as power on/off, input voltage indication, power indication, etc |
7 |
Working temperature range |
-30-55℃ |
As long as it can start at low temperature and reduce the load by 10%, it's enough |
8 |
Storage temperature range |
-40-70℃ |
|
9 |
Storage humidity range |
5% -95% no condensation |
|
Ⅳ |
Structural characteristics |
1 |
Product size |
425mm*300mm*115.4mm |
L*W*H |
2 |
Net weight |
11Kg |
|
3 |
Cooling method |
Forced air cooling |
|
V |
Safety certification requirements |
1 |
TUV Laboratory |
UL 458 |
|
2 |
CSA 22.2 No.107.1-01 |
|
3 |
Meet FCC Part 15 Class A and IC mark ICES-003 |
TBD |